![Obelindia](i/data-logger1.jpg)
Data Logger
Model: -
High performance Stand-alone system having huge capacity for Data storage with 8GB SD Card (2 million per GB). Local display monitored parameters with LCD and keypad. Built-in Real-Time Clock calendar and synchronized with CDRPS.
Sensors connection with Analog, 4-20ma, Pulse input ports, RS485, RS232 and SDI 12.
On Board 24Bit-ADC for Analog channels measurement. USB Virtual com port. Short circuit protected sensor ports. Watch Dog Timer System
The Analog/digital/SDI channel in the datalogger is compatible to all the sensors supplied. Compact rechargeable maintenance free battery.
Compact solar panel with Charger circuit. switchable modem power and sensors power to further reduce power consumption.
DATASHEET FOR NON-VENTED PRESSURE SENSOR
Model |
|
VEGAWELL 52 |
Process Connection/Material | Straining Clamp/SS316L | |
Transmitter type | Two-wire for 4..20 mA/4-wire for PT-100 | |
Process temperature | -20...80degC | |
Cable Material | PUR | |
Sensor Material/Sensor Diameter | SS316L/22mm | |
Seal Material | FKM | |
Sealing concept | Double sealing | |
Sensor Diaphragm | ceramic | |
Pressure type | Absolute pressure(Non-Vented type) | |
Accuracy | 0.1%F.S | |
Reproducibility | Included in the accuracy. | |
Temperature Coefficient | 0.005% full scale / degree | |
Overload pressure | 9...20 times full scale for the above-Mentioned ranges | |
Burst Pressure | Higher than overload pressure (> 3 times full scale) | |
Long Term Stability | 0.1% full scale / year | |
Electronics | Two-wire 4 ... 20 mA/HART + Four-wire PT100 |
|
Measuring range | 0..2.5 bar/0...5 bar /0...10bar/0..25bar/ | |
Temperature element & Meas.range |
PT100: 0...80°C | |
Overvoltage protection class/category |
III/III | |
Ambient temperature | -40....80degC | |
Voltage supply | 9.6...35VDC | |
Certificate | Calibration certificate | |
Operating instruction in | EN-ENGLISH | |
Ingress Protection | IP 68 | |
Resolution | 3 mm/lmicroA | |
Temperature accuracy | +/- 0.2 deg.0 |
- Low Power consumption.
- On Board 24Bit-ADC for Analog channels measurement.
- USB Virtual com port. Short circuit protected sensor ports.
- Watch Dog Timer System Reset upon microprocessor Failure.
- Display 2X16 Alphanumerical Display.
- External display support with RS485 option.
- Data Logger IEC certified as per IEC 68-2-1 and IEC 68-2-2 Log Data and adverse weather triggering Alarm flags transmission through GSM/GPRS, Satellite.
- Hydrology
- Meterology
- Environmental applications
- Agriculture